Home > News > Content
What Is The Condition Of The Screw Conveyor?
- Oct 27, 2017 -

1, reducer output shaft bearing high temperature. The temperature at the input shaft is normal. This is because the screw shaft center money offset or reducer output shaft bearing burned, the first, the end bearing loose. Need to release the reducer output shaft and screw shaft coupling, re-calibration installation.

2, the output shaft of the reducer output temperature is normal, the input shaft temperature is high. This is due to the motor fixed components loose or reducer output shaft bearing burned, need to release the reducer input shaft and the motor coupling, re-calibration installation.

3, reducer output, the input bearing at high temperature. This is due to the reducer fixed bolt loose or reducer both ends of the bearing burned, the need to reducer both ends of the coupling are released to re-calibrate the installation! Tongchang professional production of screw conveyor manufacturers, for your 24-hour service.